Two Phase Rack Level Liquid Cooling Solution

Two Phase Rack Level Liquid Cooling Solution

The power consumption of computing silicon, such as CPU and GPU, continues to push envelope of existing thermal solutions in IT technology. The demands of the thermal technologies for IT gears are not satisfied by functioning solutions only. High power efficiency is usually deterministic to the success of thermal solutions.

In this whitepaper, Wiwynn investigated a “Two phase Cooling” thermal solution for meeting upcoming challenges. Dielectric fluid is introduced as a working fluid that is pumped to hot chips and transported heat to the rear door heat exchanger (RDHx). The heat is then ejected from fluid to air. This solution takes advantages of the high power dissipating ability of liquid cooling in limited space. Dissipating heat to the hot aisle through RDHx requires no data center facility change. In addition, single- and two-phase liquid cooling systems are also discussed and evaluated. Controlled parameters are evaluated in the thermal model to derive the best efficient operation point.

The proposed solution extends the cooling solution to rack level gains more cooling area with bigger fans in the fan wall. By using dielectric fluid as the working liquid, liquid leakage will not result in short-circuits. Heat is finally transferred into the air so it requires no data center facility change and no serviceability change. The component temperature in the two-phase region is more uniform. Controlling the dielectric fluid in two-phase region will lead to higher cooling efficiency.

Leave your contact information to download the whitepaper.

White Paper: Platform Optimization for Performance and Endurance with QLC and Cloud Storage Acceleration Layer

1 min read

White Paper: Platform Optimization for Performance and Endurance with QLC and Cloud Storage Acceleration Layer

High-density QLC SSDs break the 4 KiB assumptions baked into today’s storage stacks: their larger indirection units inflate write-amplification,...

Read More
White Paper: Best Practices and Integration Strategies for XPU and 224Gbps in 3D Torus Rack-Level Topology

1 min read

White Paper: Best Practices and Integration Strategies for XPU and 224Gbps in 3D Torus Rack-Level Topology

AI and large-language-model clusters are straining the limits of traditional fat-tree and star networks. When tens of billions of parameters move...

Read More
White Paper: Innovative Two-Phase Cold Plate Solutions for Future High-Power AI Chips

1 min read

White Paper: Innovative Two-Phase Cold Plate Solutions for Future High-Power AI Chips

AI accelerators and next-gen HPC processors are already nudging past the one-kilowatt mark, making single-phase liquid loops struggle with soaring...

Read More