1 min read

Two Phase Rack Level Liquid Cooling Solution

Two Phase Rack Level Liquid Cooling Solution

The power consumption of computing silicon, such as CPU and GPU, continues to push envelope of existing thermal solutions in IT technology. The demands of the thermal technologies for IT gears are not satisfied by functioning solutions only. High power efficiency is usually deterministic to the success of thermal solutions.

In this whitepaper, Wiwynn investigated a “Two phase Cooling” thermal solution for meeting upcoming challenges. Dielectric fluid is introduced as a working fluid that is pumped to hot chips and transported heat to the rear door heat exchanger (RDHx). The heat is then ejected from fluid to air. This solution takes advantages of the high power dissipating ability of liquid cooling in limited space. Dissipating heat to the hot aisle through RDHx requires no data center facility change. In addition, single- and two-phase liquid cooling systems are also discussed and evaluated. Controlled parameters are evaluated in the thermal model to derive the best efficient operation point.

The proposed solution extends the cooling solution to rack level gains more cooling area with bigger fans in the fan wall. By using dielectric fluid as the working liquid, liquid leakage will not result in short-circuits. Heat is finally transferred into the air so it requires no data center facility change and no serviceability change. The component temperature in the two-phase region is more uniform. Controlling the dielectric fluid in two-phase region will lead to higher cooling efficiency.

Leave your contact information to download the whitepaper.

White Paper: Testing Apparatus to Facilitate Validation in Immersion Cooling Environment

1 min read

White Paper: Testing Apparatus to Facilitate Validation in Immersion Cooling Environment

As the chip industry moves beyond an era of rapid development, immersion cooling has emerged as a critical technology thanks to its superior cooling...

Read More
White Paper: Innovative Manufacturing Testing Platform of Immersion Cooling Technology

1 min read

White Paper: Innovative Manufacturing Testing Platform of Immersion Cooling Technology

This research introduces an innovative immersion cooling testing platform equipped with dedicated fixtures that streamline production and debugging....

Read More
White Paper: Deployment of an ORv3 Architecture Server Within Intel Open IP Single-Phase Immersion Cooling Tank

1 min read

White Paper: Deployment of an ORv3 Architecture Server Within Intel Open IP Single-Phase Immersion Cooling Tank

Wiwynn is participating in Intel’s Open IP collaboration program by integrating a 1OU computing server, compliant with the Open Compute Project (OCP)...

Read More